Outcome of Volar Barton Fractures Treated with Locking Compression Plates: A Cross-Sectional Study

Volar Barton Fractures Treated with Locking Compression Plates

Authors

  • Ahmed Raza Laghari Orthopaedics, Ghulam Mohammed Mahar Medical College / Civil Hospital Sukkur Pakistan
  • Sijad Ahmed Mahar Department of Orthopaedics, Ghulam Mohammed Mahar Medical College Sukkur, Pakistan
  • Hussain Bux Palh Department of Orthopaedics, Gambat Medical college Pir Syed Abdul Qadir Shah Jellani Institute of Medical Science GIMS Gambat, Pakistan
  • Waseem Ahmed Department of Orthopaedics, Muhammad Medical College and Hospital Mirpurkhas, Pakistan
  • Ali Muhammad Bhutto Department of Orthopaedics, Ghulam Mohammed Mahar Medical College / Civil Hospital Sukkur, Pakistan
  • Farukh Hussain Department of Orthopaedics, Jinnah Postgraduate Medical Center, Karachi, Pakistan
  • Niaz Hussain Keerio Department of Orthopaedics, Muhammad Medical College and Hospital Mirpurkhas, Pakistan

DOI:

https://doi.org/10.54393/pjhs.v3i05.178

Keywords:

locking compression plates, open reduction and internal fixation, volar Barton fracture.

Abstract

Volar Barton fracture is the fracture of distal radius bone associated with ventral displacement. It is an oblique intra-articular fracture. Objective: To investigate the results, both functional and radiological, of open reduction and internal fixation with locking compression plates of the volar Barton fracture. Methods: A total of fifteen patients were included in this study. All of the participants had volar fragment type B3 fractures of the wrist. All the patients underwent open reduction to treat the fracture. Internal fixation was done using a locking compression plate (LCP). Out of a total of 15 patients, 10 were male and 5 females. The most common cause, almost 67 %, of the fracture was a road traffic accident (RTA). The mean age of the patients was 33 years, ranging from 21 to 55 years. All the patients had their respective surgeries within 7 days of the fracture accident. Quick Dash score-, and Gartland and Werley score were used to assess the function of the hand and wrist. Results: All the fractures took the meantime of 8 weeks for the bone union. The mean Quick Dash score was 10, ranging from 0 to 60. According to Gartland and Werley’s score, 9 patients were excellent, 4 patients were good and 2 were fair. No postoperative complication occurred. Conclusions: Open reduction and internal fixation with locking compression plates of the volar Barton fracture is an effective treatment for functional and radiological restoration.

References

Szymanski JA, Reeves RA, Carter KR. Barton's Fracture. [Updated 2022 Jun 11]. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2022 Jan.

White JS. Fractures of the distal radius. Advanced Emergency Nursing Journal. 2013 Jan; 35(1):8-15.

Pillai HB, Sankar S, Rawat SS, Arya S, Jadhav P. The functional outcome volar Barton fracture treated by open reduction and internal fixation with T plate–a prospective study. International Journal of Contemporary Medical Research. 2020;7(6): F7-11.

Nellans KW, Kowalski E, Chung KC. The epidemiology of distal radius fractures. Hand clinics. 2012 May; 28(2):113-25.

Von Recum J, Matschke S, Jupiter JB, Ring D, Souer JS, Huber M, et al. Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures. Bone & Joint Research. 2012 Jun;1(6):111-7.

Rosenauer R, Pezzei C, Quadlbauer S, Keuchel T, Jurkowitsch J, Hausner T, et al. Complications after operatively treated distal radius fractures. Archives of Orthopaedic and Trauma Surgery. 2020 May; 140(5):665-673. doi: 10.1007/s00402-020-03372-z.

Carli PD. Dorsal Plating of Distal Radius Fractures. In Wrist and Elbow Arthroscopy with Selected Open Procedures 2022;471-492.

Abdel-Wahed M, Khater AA, El-Desouky MA. Volar locking plate fixation for distal radius fractures: did variable-angle plates make difference? International orthopaedics. 2022 Sep; 46(9):2165-2176. doi: 10.1007/s00264-022-05469-z.

Plant CE, Hickson C, Hedley H, Parsons NR, Costa ML. Is it time to revisit the AO classification of fractures of the distal radius? Inter- and intra-observer reliability of the AO classification. The Bone & Joint Journal. 2015 Jun; 97-B(6):818-23. doi: 10.1302/0301-620X.97B6.33844.

Jalil SA, Mughal RA, Haque SN, Shah RA. Treatment outcome of volar Barton fracture fixed with locking compression plates. Journal of surgery Pakistan. 2010; 26(4):265-8.

Fu Q, Zhu L, Yang P, Chen A. Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials. Indian journal of orthopaedics. 2018 Dec; 52(6):602-610. doi: 10.4103/ortho.IJOrtho_601_16.

Qayoom I, Shafi T, Rafeeq M. Evaluation of clinical and functional outcome of open reduction and internal fixation with volar plating in Volar Barton’s fracture of distal radius.

Dai M, Wu C, Liu H, Wang I, Yu C, Wang K, et al. Treatment of volar Barton's fractures: comparison between two common surgical techniques. Chang Gung medical journal. 2006 Jul; 29(4):388.

Mirarchi AJ and Nazir OF. Minimally Invasive Surgery: Is There a Role in Distal Radius Fracture Management? International musculoskeletal medicine. 2021 Feb;14(1):95-100. doi: 10.1007/s12178-020-09689-x.

Selles CA, Mulders MAM, Winkelhagen J, van Eerten PV, Goslings JC, Schep NWL; VIPAR Collaborators. Volar Plate Fixation Versus Cast Immobilization in Acceptably Reduced Intra-Articular Distal Radial Fractures: A Randomized Controlled Trial. The Journal of Bone and Joint Surgery. 2021 Nov; 103(21):1963-1969. doi: 10.2106/JBJS.20.01344.

Chung KC, Cho HE, Kim Y, Kim HM, Shauver MJ; WRIST Group. Assessment of Anatomic Restoration of Distal Radius Fractures Among Older Adults: A Secondary Analysis of a Randomized Clinical Trial. JAMA Network Open. 2020 Jan; 3(1): e1919433. doi: 10.1001/jamanetworkopen.2019.19433.

Quadlbauer S, Pezzei C, Jurkowitsch J, Rosenauer R, et al. Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate. Archives of Orthopaedic and Trauma Surgery. 2018 Dec;138(12):1773-1782. doi: 10.1007/s00402-018-3051-5.

Alter TH, Sandrowski K, Gallant G, Kwok M, Ilyas AM. Complications of Volar Plating of Distal Radius Fractures: A Systematic Review. The Journal of Wrist Surgery. 2019 Jun; 8(3):255-262. doi: 10.1055/s-0038-1667304.

Kong L, Kou N, Wang Y, Lu J, Tian D, Zhang B. The Necessity of Restoration of Radiologic Parameters by Closed Reduction in Elderly Patients with Distal Radius Fractures. Medical science monitor basic research. 2019 Sep; 25:6598-6604. doi: 10.12659/MSM.915824.

Çalbıyık M and Ipek D. Use of Volar Locking Plate Versus Intramedullary Nailing for Fixation of Distal Radius Fractures: A Retrospective Analysis of Clinical and Radiographic Outcomes. Medical science monitor basic research. 2018 Jan; 24:602-613. doi: 10.12659/msm.908762.

Downloads

Published

2022-10-31
CITATION
DOI: 10.54393/pjhs.v3i05.178
Published: 2022-10-31

How to Cite

Raza Laghari, A. ., Ahmed Mahar, S. ., Bux Palh, H. ., Ahmed, W. ., Bhutto, A. M. ., Hussain, F. ., & Keerio, N. H. . (2022). Outcome of Volar Barton Fractures Treated with Locking Compression Plates: A Cross-Sectional Study: Volar Barton Fractures Treated with Locking Compression Plates. Pakistan Journal of Health Sciences, 3(05), 142–146. https://doi.org/10.54393/pjhs.v3i05.178

Issue

Section

Original Article

Plaudit

Most read articles by the same author(s)