Abstract

With advancement in the endodontic technology there is a quest to introduce root canal instruments showing superior performance by removing minimum amount of sound root dentine and retaining the original shape of the root canal. Objective: To compare the changes in the width of simulated curved canals prepared with ProFile and ProTaper rotary system. Methods: This in-vitro, Quasi Experimental study was carried out in the Dental section of The Aga Khan University Hospital. Pre and post instrumentation photographs (images) of sixty resin blocks prepared with ProFile and ProTaper rotary instruments respectively (with 1:10 magnification) were superimposed using software Adobe Photoshop 6.0. Measurements were done on print out of composite images. Measurements of change in width (resin removed) were recorded along the length of canal at 12 points. Results: Two rotary system showed statistically significant difference in simulated curved canals width after preparation. ProTaper rotary instruments showed more resin removal at the inner walls of the canal at 1, 8-12mm from the apex and more resin removal at outer wall of canal at 9-12 mm from apex. Conclusions: ProFile and ProTaper rotary files showed statistically significant difference in canal width after instrumentation. ProTaper rotary files showed more resin removal in canals towards the inner wall and coronal part of the outer wall.

References

Khapre R, Sarve J, Makade C. Comparative Study of Endodontic Files with Various Cross Sections with Varying Threads. Advanced Science, Engineering and Medicine. 2014 Jan; 6(1):75-80. doi: 10.1166/asem.2014.1454

Abd El Hamid HM. Comparative study between ProTaper next and 2 shape NI-TI rotary files on maintanence of canal curvature using radiovisiography (RVG) (an in vitro study). Egyptian Dental Journal. 2019 Jul; 65(3-July (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)):3037-44. doi: 10.21608/edj.2019.72700

Kim H, Jeon SJ, Seo MS. Comparison of the canal transportation of ProTaper GOLD, WaveOne GOLD, and TruNatomy in simulated double-curved canals. BMC Oral Health. 2021 Dec; 21(1):1-7. doi: 10.1186/s12903-021-01854-z

Stavileci M, Hoxha V, Görduysus Ö, Tatar I, Laperre K, Hostens J, et al. Effects of preparation techniques on root canal shaping assessed by micro-computed tomography. Medical science monitor basic research. 2013; 19:163. doi: 10.12659%2FMSMBR.889350

Schilder H. Cleaning and shaping the root canal. Dental clinics of north America. 1974 Apr; 18(2):269-96. doi: 10.1016/S0011-8532(22)00677-2

Hülsmann M, Peters OA, Dummer PM. Mechanical preparation of root canals: shaping goals, techniques and means. Endodontic topics. 2005 Mar; 10(1):30-76. doi: 10.1111/j.1601-1546.2005.00152.x

Gao Y, Gutmann JL, Wilkinson K, Maxwell R, Ammon D. Evaluation of the impact of raw materials on the fatigue and mechanical properties of ProFile Vortex rotary instruments. Journal of endodontics. 2012 Mar; 38(3):398-401. doi: 10.1016/j.joen.2011.11.004

Farid H, Khan FR, Rahman M. ProTaper rotary instrument fracture during root canal preparation: a comparison between rotary and hybrid techniques. Oral health and dental management. 2013; 12(1):50.

Park HJ, Seo MS, Moon YM. Root canal volume change and transportation by Vortex Blue, ProTaper Next, and ProTaper Universal in curved root canals. Restorative Dentistry & Endodontics. 2017 Dec; 43(1). doi: 10.5395/rde.2018.43.e3

Hülsmann M. A critical appraisal of research methods and experimental models for studies on root canal preparation. International Endodontic Journal. 2022 Mar; 55:95-118. doi: 10.1111/iej.13665

Yalniz H, Koohnavard M, Oncu A, Celikten B, Orhan AI, Orhan K. Comparative evaluation of dentin volume removal and centralization of the root canal after shaping with the ProTaper Universal, ProTaper Gold, and One-Curve instruments using micro-CT. Journal of Dental Research, Dental Clinics, Dental Prospects. 2021; 15(1):47. doi: 10.34172%2Fjoddd.2021.009

Fernandes Zancan R, Hadis M, Burgess D, Zhang ZJ, Di Maio A, Tomson P, et al. A matched irrigation and obturation strategy for root canal therapy. Scientific Reports. 2021 Feb; 11(1):1-3. doi: 10.1038/s41598-021-83849-y

Mounce R. Negotiating challenging mid root curvatures: rounding the bend. Dentistry today. 2007 Feb; 26(2):108-10.

Badar SB, Zafar K, Ghafoor R, Khan FR. Changes in canal width and angle in curved canals in the resin blocks: Pro taper next versus one shape instruments. Journal of Pakistan Medical Association. 2020 Dec; 70(12(B)):2371-2375. doi: 10.47391/JPMA.335. PMID: 33475546.

Kandaswamy D, Venkateshbabu N, Porkodi I, Pradeep G. Canal-centering ability: An endodontic challenge. Journal of Conservative Dentistry. 2009 Jan; 12(1):3-9. doi: 10.4103/0972-0707.53334

de Cristofaro Almeida G, Aun DP, Resende PD, Peixoto IFDC, Viana ACD, Buono VTL, et al. Comparative analysis of torque and apical force to assess the cutting behaviour of ProTaper Next and ProTaper Universal endodontic instruments. Australian Endodontic Journal. 2020 Apr; 46(1):52-59. doi: 10.1111/aej.12351

Madani Z, Soleymani A, Bagheri T, Moudi E, Bijani A, Rakhshan V. Transportation and Centering Ability of Neoniti and ProTaper Instruments; A CBCT Assessment. Iranian Endodontic Journal. 2017; 12(1):43-49. doi: 10.22037/iej.2017.09

Christofzik D, Bartols A, Faheem MK, Schroeter D, Groessner-Schreiber B, Doerfer CE. Shaping ability of four root canal instrumentation systems in simulated 3D-printed root canal models. PLoS One. 2018 Aug; 13(8):e0201129. doi: 10.1371/journal.pone.0201129.

Giovannone T, Migliau G, Bedini R, Ferrari M, Gallottini L. Shaping outcomes using two Ni-Ti rotary instruments in simulated canals. Minerva Stomatologica. 2008 Apr; 57(4):143-54

Ayar LR and Love RM. Shaping ability of ProFile and K3 rotary Ni-Ti instruments when used in a variable tip sequence in simulated curved root canals. International Endodontic Journal. 2004 Sep; 37(9):593-601. doi: 10.1111/j.1365-2591.2004.00851.x

Yang GB, Zhou XD, Zhang H, Wu HK. Shaping ability of progressive versus constant taper instruments in simulated root canals. International Endodontic Journal. 2006 Oct; 39(10):791-9. doi: 10.1111/j.1365-2591.2006.01151.x

Downloads

Published

2022-10-31
CITATION
DOI: 10.54393/pjhs.v3i05.184
Published: 2022-10-31

How to Cite

Faisal, A. ., Farid, H., & Ghafoor, R. . (2022). A Comparison of Canal Width Changes in Simulated Curved Canals prepared with Profile and Protaper Rotary Systems : Canal Width Changes in Simulated Curved Canals. Pakistan Journal of Health Sciences, 3(05), 55–59. https://doi.org/10.54393/pjhs.v3i05.184

Issue

Section

Original Article